relay zero
relay 0 zero is the hot shoe center contact switch. switches the center contact of the camera hot shoe to our [main] or [2nd] hot shoe center contacts.
The ground from the camera hot shoe is wired directly to both the [main] and [2nd] hot shoes.
relay one
relay 1 closes the contacts of the camera wired release.
A list of user defined wait times is at end of this description.
Sequence of events.
start with relay 0 off
relay 1 off
user defined wait1 in ms
loop for [start] button
relay 1 on (camera)
user defined wait2 in ms
relay 1 off
user defined wait3 in ms
relay 0 on
user defined wait4 in ms
relay 1 on
wait2
relay 1 off
return to start
wait times.
in milliseconds
Ultimately the user will need to enter their own wait times for all waits. The acceptable ranges are listed below.
wait1 = wait after board found and sets relay zero and one = default 250ms, allowed user range 0 to 10000
wait2 = shutter activation period = default 500ms, allowed user range 250 to 10000
wait3 = wait from end shutter activation and possible user using a long shutter time. = default 250ms, allowed user range 0 to 10000
wait4 = default 250ms, allowed user range 0 to 10000
end.